MECHANICAL DIAGRAM (CLICK TO ZOOM)
TYPICAL SPECIFICATIONS
| Output frequency | 14.0 to 14.50 GHz | External reference level | -5 to +5 dBm |
| Output frequency Fully Extended | 13.75 to 14.50 Ghz | 10Mhz external reference noise aximum | -135 dBc/Hz at 100 Hz -140 dBc/Hz at 1 kHz -150 dBc/Hz at 10 kHz |
| Input frequency 1 Input frequency 2 |
950 to 1450 MHz 950 to 1700 MHz |
Gain (including variation over temperature and frequency) | 50 dB min 60 dB max |
| Output P1dB minimum | 36 dBm | Gain stability over temperature | ±2.25 dB at any constant frequency |
| L.O. frequency 1 L.O. frequency 2 |
13.05 GHz 12.80 GHz |
Gain stability in-band at any constant temperature | ±1.0 dB in any 54 MHz band ±3.0 dB over full 750 MHz band |
| Input VSWR maximum | 2.0 : 1 | ||
| Output VSWR maximum | 2.1 : 1 | ||
| Phase noise (SSB) maximum | -70 dBc/Hz at 1 kHz -80 dBc/Hz at 10 kHz -90 dBc/Hz at 100 kHz |
||
| External reference signal frequency | 10 MHz | ||
| Power requirements | +15 to +24V supplied through center conductor of IF cable | ||
| Power consumption maximum | 45 W | ||
| Dimensions | 228 (L) x 125 (W) x 65 (H) mm (9.0 x 4.9 x 2.6 in) | ||
| Weight | 1.9 kg / 4.2 lb |
HOW TO ORDER KU-BAND 1041XRTE
![]() |