TYPICAL SPECIFICATIONS
| Noise figure maximum | 0.6 to 0.8 dB depending on model number | Conversion gain | 64 dB |
| L.O. stability maximum (over temperature) | ±15 to ±50 ppm | Output P1dB maximum | 8 dBm |
| Phase noise (SSB) maximum | -65 dBc/Hz at 1 kHz -80 dBc/Hz at 10 kHz -100 dBc/Hz at 100 kHz |
Power requirements | +15 to +24V supplied through center conductor of IF cable |
| Input VSWR maximum | 2.2 : 1 | Current drain maximum | 120 mA |
| Output VSWR maximum | 2.2 : 1 | Dimensions | 85 (L) x 43 (W) x 43 (H) mm (5.3 x 1.7 x 1.7 in) |
| Weight | 120 g / 4.2 oz |
FREQUENCY BANDS AVAILABLE
| Typical service | 4000A | 4000B | 4000C | 4000D | 4000K |
| Input frequency (Ghz) | 11.70 to 12.20 GHz | 12.25 to 12.75 GHz | 10.95 to 11.70 GHz | 12.20 to 12.70 GHz | 11.20 to 11.70 GHz |
| L.O. frequency (GHz) | 10.75 GHz | 11.30 GHz | 10.00 GHz | 11.25 GHz | 10.25 GHz |
| Output frequency (MHz) | 950 to 1450 MHz | 950 to 1450 MHz | 950 to 1700 MHz | 950 to 1450 MHz | 950 to 1450 MHz |
HOW TO ORDER KU-BAND 4000
![]() |