The IBAC 2 is a continuous, real-time air monitor that alarms in less than 60 seconds when an airborne bio-threat is present. It uses UV-Laser induced fluorescence to discriminate biological organisms from background particles, reliably detecting all four classes of biological agents at concentrations below 100 ACPLA with low false alarm rates and no consumables. The IBAC 2 system can operate independently, as part of a network configuration to form the “first tier” of a building protection system, or via battery power module for mobile detection capability. The system automatically alarms upon detection, collects and preserves samples for confirmatory analysis, and transmits data to command and control centers. From long-term, fixed installations to short, mission-based tactical applications, the IBAC 2 is the most mature and widely deployed biological trigger on the market today.

AFFORDABLE, REAL-TIME WARNING CAPABILITY FOR BIO-AEROSOL THREATS
Detects spores, bacteria, virus, and toxins
• Sensitivity below 100 ACPLA with high confidence and low false alarm rates
• Autonomous 24/7/365 operation with no consumables
• Alarm automatically triggers sample collection
• Detection algorithms for indoor and outdoor use

COMPACT, LIGHTWEIGHT, AND RUGGED
Integrates with facility monitoring and control systems
• Mass transit security 
• Building protection and Critical Infrastructure Protection 
• Mobile labs
• Integrated CBRNE systems and Force protection

RELIABLE
Most mature and widely deployed bio-trigger device
• More than 1,000 units deployed world wide
• US Government validated 
• Low sustainment cost and high Mean Time Between Failure (MTBF) rates
• Has been operated for >5,000,000 hours in relevant environments

KEY SPECIFICATIONS
DFU collector

Sampling Method: Dry collection

Power Consumption: 60W

Max Flow Rate: 100 L/min 

Particle Size: 1 to 10 microns 

Collection Media: Dry sampling - polyester felt filters (47mm diameter, 1 micron) 

Sample Recovery: Particle extraction from filter performed in vial with liquid buffer

location GPS
sample collection Integrated with DFU
sample introduction Airborne particles; triggered aerosol sample collector
sample phase Aerosol; flow rate 4.0 L/min (0.14 ft3/min)
sampling and analysis Continuous sampling 24/7/365; indoor/outdoor alarm settings; analysis time configurable down to 1 second
sensing technology UV Laser Induced Fluorescence (LIF)
sensitivity <100 particles/L of air
threats Spores, vegetative bacteria, viruses, and toxins; particle size: 0.7 – 10 microns
Product Revision A
ELECTRICAL SPECIFICATIONS
battery Li-ion UBBL13 military battery; up to 14 hrs runtime; charge <4 hrs
cold start time <5 mins
input power 100-240 VAC (adapter supplied); 18-36 VDC
power consumption 20 watts (normal detector operation) 75 watts (with collector running)
INTERFACE SPECIFICATIONS
data storage Internal 2 GB MicroSD memory card; stores over 1 yr of data
display and alerts On-board LED for visual indication; full display via software on external computer
outputs Particle data, sensor diagnostics, bio-alarm, and fault
training requirements <2 hrs
M and C SPECIFICATIONS
m and c Ethernet, RS-232, Embedded wireless Wifi
ENVIRONMENTAL SPECIFICATIONS
humidity 5% to 95%, non-condensing
IP rating IP66
temperature operational -20°C to +50°C
temperature storage -40°C to +70°C
PHYSICAL SPECIFICATIONS
enclosed accessories Mounting bracket, case
enclosure Aluminum
product height 299 mm
product length 240 mm
product weight 5.5 kg
product width 165 mm